MonoLith Battery Systems

28-40V Battery Packs

Compact power for robotics, AGVs, and telecom infrastructure

The 28-40V band delivers compact energy storage for autonomous mobile robots, light industrial AGVs, and telecom backup systems. MonoLith packs in this range span 28.8-39.6V nominal with 3.5-4.8 kWh capacity and up to 28 kW discharge. This voltage aligns with 24V nominal bus standards while providing dynamic headroom for rapid acceleration and sustained current draw. The 8 configurations available let engineers optimize for torque delivery in confined spaces, critical for warehouse automation and precision guidance systems.

Available Configurations
8
Voltage Range
28.8-39.6V
Power Range
14-28 kW
Open in PackForge Configurator

Representative Configurations

Representative configurations in the 28-40V band, ordered by voltage.

Part NumberVoltageEnergyDischarge PowerCapacityMass
1SPA-008S1P-003.5A128.8 V3.5 kWh14 kW120.0 Ah41 kg
1SPA-009S1P-003.9A132.4 V3.9 kWh16 kW120.0 Ah44 kg
1SPA-010S1P-004.3A136.0 V4.3 kWh18 kW120.0 Ah47 kg
1SPA-011S1P-004.8A139.6 V4.8 kWh20 kW120.0 Ah51 kg
1SPC-008S1P-003.5A128.8 V3.5 kWh20 kW120.0 Ah41 kg
1SPC-009S1P-003.9A132.4 V3.9 kWh23 kW120.0 Ah44 kg
1SPC-010S1P-004.3A136.0 V4.3 kWh25 kW120.0 Ah47 kg
1SPC-011S1P-004.8A139.6 V4.8 kWh28 kW120.0 Ah51 kg

Showing 8 of 8 matching configurations. View and filter all 8 in PackForge →

Mobile Robotics and Warehouse AGVs

The 28-40V sweet spot dominates autonomous mobile robot platforms where space and weight constraints demand efficient power delivery. This voltage band aligns with industry-standard 24V nominal infrastructure while providing the dynamic headroom needed for rapid acceleration and sustained high-current draw during mission-critical operations.

Engineers select this band for seamless integration with legacy PLC systems and soft-start drive architectures. The low inductance characteristics of MonoLith cell topology reduce transient spikes, protecting sensitive motor controllers and extending drivetrain longevity in environments with frequent start/stop cycles.

Telecom Backup and Edge Infrastructure

Telecom infrastructure relies on 28-36V DC buses for remote repeater stations and distributed antenna systems. MonoLith packs in this band provide the predictable discharge curves and thermal stability required for 99.9% uptime SLAs, even in high-ambient outdoor enclosures.

The modular form factor supports N+1 redundancy configurations, allowing field technicians to swap depleted units without system shutdown. Peak power headroom ensures rapid response to transient network loads during failover events.

Compact Industrial Automation

Precision motion control in compact spaces-pick-and-place arms, gantry systems, and collaborative robot joints-demands reliable, space-efficient power. MonoLith 28V packs integrate directly into DIN-rail mounted converters and distributed power architectures.

Engineering teams can design single-battery autonomous systems with multi-hour duty cycles, reducing the complexity of multi-stage battery management and simplifying thermal management across the entire platform.

Ready to spec your system?

Use PackForge to filter by exact voltage, energy, and power — then export a pre-filled RFQ with one click. No NRE, no custom tooling, lead times measured in weeks.

Open PackForge

Browse by spec